OpenTracker USB User’s Manual 12
11.4. Warm Boot vs. Cold Boot
If the unit is already powered on and operating when you click the ‘Connect’
button, the program attempts a ‘warm boot’ operation to put the device into
configuration mode. If the firmware has been corrupted, i.e. by a failed upgrade,
it may fail to enter configuration mode. You can correct this by performing a
‘cold boot’ - power the unit off and power it on again after clicking ‘Connect’.
11.5. Working Offline
If you need to edit a configuration without connecting the tracker, click the
‘Offline’ button. You will need to have a saved configuration file to work from.
11.6. Main Configuration Window